Industrial seawater RO system

Industrial Seawater RO Treatment Systems | Reverse Osmosis Desalination Solutions

Price

$0.00 $0.00
Save $0.00
Free shipping

Quantity

Free worldwide shipping
Free returns
Sustainably made
Secure payments

High-Capacity RO Seawater Desalination Plant

Our industrial RO seawater desalination plants provide a capacity range of 2m³/hour to 2500m³/day. For lower capacity needs, check out our commercial RO desalination machines.

How Does an Industrial RO Seawater Desalination Plant Work?

All RO desalination systems begin with a booster pump, which feeds raw water into pretreatment tanks. Depending on capacity, the size and number of pretreatment tanks can vary. Since seawater has a high TDS (Total Dissolved Solids) and is highly corrosive, we use FRP (Fiber Reinforced Plastic) or carbon steel materials for durability.

Key Pretreatment Components:

  • Sand Media Filter Tank – Removes suspended solids, sediment, and turbidity.
  • Activated Carbon Filter Tank – Eliminates chlorine, organic contaminants, odors, and unwanted colors.
  • Softener Tank with Ion Exchange Resin – Prevents scaling by reducing hardness.

Reverse Osmosis Seawater Purification System

The RO purification system removes: ✅ Dissolved salts
Heavy metals
Bacteria & viruses
Organic & inorganic solids
Proteins, dyes, and unwanted particles

Step-by-Step Water Filtration Process

  1. Pretreatment Stage: Filters out large suspended solids and organic contaminants.

  2. Cartridge Filter Housing (Security Filter): Uses 1µm or 5µm PP filters to remove finer particles before entering high-pressure pumps.

  3. High-Pressure Pump & Membrane Filtration:

    • We offer Grundfos, Danfoss, CNP, or Chunke high-pressure pump options.
    • RO membranes from DOW Filmtec, Toray, Vontron, Hydranautics, and LG ensure 99% salt rejection.
    • Membranes available in 4040 and 8040 sizes based on system capacity.
  4. Post-Treatment & Chemical Dosing:

    • Anti-scalant & anti-fouling agents prevent membrane clogging.
    • pH adjustment, sterilization, and disinfection chemicals for improved water quality.
    • Optional CIP (Clean-In-Place) System extends membrane lifespan.

Industrial RO Desalination Machine Specifications

Membrane Sizes & Flow Rates for SWRO Systems

Model Permeate Flow Rate (L/H) Membrane Size Quantity
CK-RO-2000L 2000 8040 3
CK-RO-3000L 3000 8040 3-4
CK-RO-4000L 4000 8040 4-6
CK-RO-5000L 5000 8040 5-6
CK-RO-6000L 6000 8040 8
CK-RO-8000L 8000 8040 10-12
CK-RO-10000L 10000 8040 12-15
CK-RO-15000L 15000 8040 20
CK-RO-20000L 20000 8040 28
CK-RO-30000L 30000 8040 40-45
CK-RO-45000L 45000 8040 50-60
CK-RO-100000L 100000 8040 120-150
CK-RO-200000L 200000 8040 240-300

What is a Reverse Osmosis (RO) Desalination System?

A reverse osmosis (RO) desalination system is designed to remove salt from seawater, making it usable for industrial, municipal, and drinking water applications. Our industrial seawater desalination plants use RO membrane technology, which ensures 99% salt removal, delivering fresh and clean water efficiently.

Why Choose Reverse Osmosis for Seawater Purification?

  • High Salt Removal Efficiency – Over 99% salt rejection.
  • No Chemical Phase Change – Operates at normal temperature, reducing energy costs.
  • Compact Design – Requires minimal space while providing high-capacity filtration.
  • Automation & MonitoringProgrammable PLC control ensures ease of operation.
  • Cost-Effective & Energy-Efficient – Lower operating costs compared to thermal desalination.

Features & Optional Upgrades for SWRO Plants

Standard Features Available Upgrades
PLC Programmable Control 🔹 Automatic Flushing System
Heavy-Duty Cartridge Filter Housing 🔹 Ozone Generator for Extra Disinfection
FRP Membrane Housing 🔹 UV Sterilization Unit
Low & High-Pressure Safety Switches 🔹 pH Control Monitoring
Liquid-Filled Pressure Gauges 🔹 Remote Monitoring System
Stainless Steel/UPVC Piping 🔹 Post-Treatment Deionization Unit

Operation Specifications for Industrial RO Desalination Machines

Specification Value
Feed Water TDS 10,000 – 42,000 ppm
Operating Pressure 48 – 80 bar
Customization for TDS > 50,000 ppm Required
Max Feed Water Temperature 42°C
pH Tolerance 3 – 11
Max Iron Content 0.05 ppm
Required Additives Anti-scalant & Anti-fouling chemicals
Feed Water Pressure 2.5 – 6 bar
Turbidity Removal Required

Industrial RO Desalination Machine – Cost Considerations

The cost of an industrial seawater desalination system is higher than that of a regular freshwater RO system. This is because:

  • High-pressure pumps are required to handle seawater’s high salinity.
  • Corrosion-resistant materials (FRP, stainless steel) increase longevity.
  • Advanced filtration membranes are used for high-recovery desalination.

Why Choose Our Industrial Seawater RO Desalination Systems?

Customizable to Your Water Analysis – Tailored design based on your specific water quality.
Global Quality Standards – We use ISO, FDA, and NSF-certified components.
Low Maintenance & Long Lifespan – Equipped with CIP (Clean-In-Place) system to extend membrane life.
Competitive Pricing & Cost-Efficiency – Best balance of affordability, performance, and durability.


Get a Free Consultation for Your RO Desalination Project!

Looking for a customized industrial RO seawater purification system?
💬 Contact us today for expert advice on selecting the best seawater RO treatment plant for your business.

📩 Get a Quote Now!